.jpg)
The HIDROWELL-C1-80 system is designed for leachate treatment with a capacity of 80 m³/day, using a two-stage reverse osmosis process. It reduces TDS from up to 38,000 mg/L to below 2,500 mg/L and operates at a pressure of up to 65 bar with a specific energy demand of 5.2 kWh/m³. Housed in a 40-foot container, it features PLC control and treats water to meet strict quality standards for pH, COD, BOD, and ammonia.
Section | Parameter | Value |
---|---|---|
Model Information | Type | HIDROWELL-C1-80 |
Installation | In 40’ HC container | |
Dimensions | 12,192 x 2,438 x 2,896 mm | |
Weight (Net/Gross) | 5,800 / 9,500 kg | |
Application | Leachate water treatment | |
Operating Parameters | Leachate water volume | 80.0 m³/day |
Treated water volume | 40.0 – 48.0 m³/day | |
Effluent volume | 32.0 – 40.0 m³/day | |
Recovery | 50 – 60 % | |
Design temperature | 20 °C | |
Operating temperature | 15–35 °C | |
Design pressure | 80 bar | |
Operating pressure | 65 bar | |
Specific energy demand | 5.2 kWh/m³ | |
Inlet water pressure | 2.5 – 5.0 bar | |
Permeate pressure | Max. 1 bar | |
Construction | Pre-treatment tank | 4.0 m³ / PP |
Homogenizing pump | CRN 5-5 | |
Booster pump | CRNE 5-7 | |
Chemical dosing unit | HF-VA-ST/C 6-10 | |
Sand filter | HF-MMF-760 A/T | |
Fine filter element | 5 µm filter cartridge | |
RO Unit Stage 1 | HF-RO-4.0 DT | |
RO Unit Stage 2 | HF-RO-3.0 ST | |
Treated water tank | 3.0 m³ / PP | |
High pressure piping | EN 1.4401 | |
Low pressure piping | PVC or PP or SS | |
Additional equipment | Control instrumentation, Motor switch box, CIP unit | |
Leachate Quality | pH | 7.5 – 8.5 |
Conductivity | 41,000 – 45,000 µS/cm | |
TDS | 35,000 – 38,000 mg/L | |
TSS | 50 – 250 mg/L | |
COD | ≤ 10,000 mg/L | |
BOD | ≤ 5,000 mg/L | |
Treated Water Quality | pH | 6.5 – 9.0 |
TDS | < 2,500 mg/L | |
COD | < 500 mg/L | |
BOD | < 250 mg/L | |
NH₃ (Ammonia) | < 50 mg/L | |
Effluent Quality | pH | 7.0 – 8.0 |
TDS | 60,000 mg/L | |
Connection | Inlet | DN 50 |
Treated water | DN 40 | |
Effluent | DN 100 | |
Electric supply | 3 × 415 V; 50 Hz | |
Installed electric power | 35.0 kW | |
Energy demand | 22.5 kW | |
Control | Controller | PLC |
Communication | Modbus | |
Display | Status, Function parameters, Error signals |